A dryer that tumbles but never warms the load is a different problem from one that runs warm and still leaves clothes damp. Start by confirming the cycle is supposed to heat, then check the power or gas supply, the lint filter and the exhaust vent. Samsung's clothes-not-dry guide uses that same order, and the NFPA dryer and washer safety tips treat a clear lint path as a safety step, not only a performance step.
Try the owner checks below first. If the drum stays cold, or you're dealing with a gas dryer and a fuel-supply question you can't verify, dryer repair in Calgary is the usual next step.

Key Takeaways
- Some cycles run cooler than others. Samsung notes that Eco Dry can operate without heat at the start of a cycle.
- Feel the drum after a short run. Any warmth means the heater is working, and the job shifts to airflow and venting.
- Electric dryers need a 240V supply. The controls can light up even when the heater is not getting enough voltage.
- On a gas dryer, confirm the valve is on and the connection is sound. If you smell gas, leave the home right away without using light switches, phones or anything that could spark, then call ATCO at 1-800-511-3447 or 911 from outside.
- A packed lint filter or a blocked vent can stop heat from building, and it is a fire risk. Clean both before you assume a part has failed.
Is it no heat, or not enough heat?
Start a regular timed or automatic cycle, not an air-fluff or no-heat setting, and wait about 30 seconds. Open the door and feel the drum.
- Any warmth means the machine is producing heat. Damp clothes from there usually point to airflow: the lint filter, the exhaust, or a load that is too large. Use the guide on a dryer not drying clothes.
- A completely cold drum is the no-heat path in this article.
If you have a Samsung model, the brand-specific walk-through is Samsung dryer not heating, including that model's vent blockage test results.
Check the supply before you open the cabinet
| Fuel | Owner check | Stop and call if |
|---|---|---|
| Electric | The dryer is on a 240V outlet, and the cord is fully seated. A 120V receptacle or a loose connection can run the motor and the panel without feeding the heater. | The breaker trips, the receptacle looks damaged, or the dryer has never heated since it was installed on that circuit. |
| Gas | The shutoff valve is open and the connection looks undisturbed. | You smell gas, hear hissing, or the valve and fittings are not something you can confirm safely. Leave the home right away without using light switches, phones or anything that could spark, then call ATCO at 1-800-511-3447 or 911 from outside. |
ATCO's gas-emergency page is the right place for a suspected leak. If you smell gas, leave the home right away without using light switches, phones or anything that could spark, then call ATCO at 1-800-511-3447 or 911 from outside. That isn't a routine service call, and it isn't something to "air out" while the dryer keeps running.
It also helps to sort what you're seeing before you go further:
- On an electric dryer, the panel and drum can run while the drum stays cold if the machine is on 120V, or if a 240V outlet or cord is loose.
- On a gas dryer, a cold drum with a working motor can mean the valve is closed, or the igniter and gas path need a technician. If you smell gas, stop and follow the ATCO steps above.
- If you feel any warmth after a short run, the heater is working and the job shifts to lint, the vent or a condenser, as in the dryer-not-drying guide.
Lint, the vent, and why a cold dryer can still be an airflow problem
Heat has to leave the cabinet through the exhaust. When lint packs the filter or the duct, temperature and airflow sensors can shut the heat off, or the load never warms through. Clean the lint filter before every load. If the filter is grimy, wash it and let it dry. Then inspect the vent hose for kinks, crushed sections and lint at the wall cap. The steps are in how to clean a dryer lint trap and how to clean a dryer vent. For a long or inaccessible run, book dryer vent cleaning in Calgary.
The NFPA safety tips make the same point in fire-safety language: keep the lint filter clean, and keep the exhaust clear and vented outdoors. Don't run a dryer with a missing, damaged or clogged lint screen.
Vented electric and gas dryers move moist air outdoors. Condenser and heat-pump models keep the moisture inside a heat exchanger and a tank, which is why the photo above shows a compressor, coils and a fan rather than a long duct. On those machines, a clogged exchanger can look like a no-heat or no-dry complaint, so clean that part as the manual describes before you assume the heater or compressor has failed. The drying-side checks live in the dryer not drying clothes guide.
When a no-heat fault needs a technician
Owner checks stop at the cycle, the supply and the lint path. Inside the cabinet, a no-heat fault can involve a heating element or gas igniter, a thermal fuse, a cycling thermostat, or, on a heat-pump dryer, the compressor and fan you see in the photo above. Those parts carry live voltage or gas, so leave them to a technician.
Call if the drum stays cold after the checks above, if a heating or temperature code stays on, or if the dryer is a gas model and you can't confirm the supply safely. InterNACHI's life-expectancy chart lists a clothes dryer at 13 years. Age alone doesn't decide the repair, but a no-heat failure on an older machine is a fair moment to weigh parts against replacement.
We charge a $100 diagnostic, credited toward labour if you go ahead. Warranty is 3 months on parts and labour. Technicians reach Airdrie, Chestermere, Cochrane, Okotoks and Calgary, often arriving the same or next day.
Dryer not heating questions
Why does the drum spin if there is no heat? The motor and the heater are separate circuits. On an electric dryer, the motor can run even when the 240V heater supply is missing.
Can I keep using a dryer that isn't heating? You can finish a load on an air setting if the machine otherwise runs normally, but don't ignore a burning smell, a tripped breaker or a gas odor. If you smell gas, leave the home right away without using light switches, phones or anything that could spark, then call ATCO at 1-800-511-3447 or 911 from outside.
Is a clogged vent only a "not drying" problem? No. Restricted exhaust can keep the heater from staying on, and the NFPA tips treat it as a fire hazard.
To book a visit, use the online form or call 587-816-2400.
In-body photo: WPA Wäschetrockner by V-ZUG AG, CC BY-SA 3.0 de. Cropped to 1990x1119 to show the compressor, coils and fan, cutting German signage from the original. This is an adaptation of the original under CC BY-SA 3.0 de.